Siemens SINUMERIK Controller
Safety · Intermediate · 30-120 minutes
Siemens 840D 27250 - PROFIsafe: configuration in DP M changed; error code
Alarm 27250 indicates that the DP master (typically an S7-300/400 PLC or integrated DP master on 840D) has detected a configuration mismatch in the PROFIBUS network topology or PROFIsafe device parameters. The SINUMERIK control cannot guarantee safe operation because the safety-relevant configuration no longer matches the validated GSD (Generic Station Description) file or the saved DP slave configuration in the NCK.
Siemens 840D 27250 - PROFIsafe: configuration in DP M changed; error code
PROFIsafe: configuration in DP M changed; error code
Siemens SINUMERIK alarm 27250: PROFIsafe: configuration in DP M changed; error code -. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 27250 indicates that the DP master (typically an S7-300/400 PLC or integrated DP master on 840D) has detected a configuration mismatch in the PROFIBUS network topology or PROFIsafe device parameters. The SINUMERIK control cannot guarantee safe operation because the safety-relevant configuration no longer matches the validated GSD (Generic Station Description) file or the saved DP slave configuration in the NCK.
Safety
Causes and Fixes
Access the DP Master configuration tool (STEP 7 Hardware Configuration or Automation Tool). Compare the current PROFIBUS node assignment, baud rate, and module GSD versions against the last known working configuration. Document any changes in slot positions, device addresses, or safety module parameters.
Do not modify DP master configuration without first backing up the current NCK safety database (use Automatic Backup function or manual SD card export).
On the SINUMERIK 840D, navigate to Diagnostics > PROFIBUS > Configuration Status. Check the stored configuration checksum (typically displayed as hexadecimal hash) and compare it against the DP master's current checksum reported in the alarm details (%1 and %2 parameters).
Re-download the DP master configuration to the S7 PLC using STEP 7 (Block Transfer or Download function). Immediately perform a full NCK system startup with cold start (MD 20050 = 0, then power cycle). This forces the NCK to re-scan and validate the entire PROFIBUS network against stored GSD files.
Cold start will clear volatile memory; ensure all part programs and offset data are saved externally.
Monitor the NCK Diagnostics > System > Boot Log for PROFIsafe initialization messages. If the checksum still mismatches, the GSD files on the DP master may be corrupted; reload the original GSD file library from the engineering station and repeat configuration download.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.