Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

26230

Siemens 26230 - Block : Protection area element , referred to in $NP_NEXT[ ],

Block: Protection area element, referred to in $NP_NEXT,

The protection area element indicated next in a protection area was not found Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The protection area element indicated next in a protection area was not found

Troubleshooting Steps

  1. 1Indicate in $NP_NEXT[...] the name of an existing protection area element.
  2. 2Clear alarm with NC START or RESET key and continue the program