Siemens SINUMERIK Controller
Safety · Intermediate · 30-120 minutes
Siemens 840D 20106 - Emergency stop set by the digitizer
Alarm 20106 indicates the digitizing unit (probe/touch trigger sensor) has detected a critical fault condition and autonomously triggered an emergency stop via the NCK safety circuit. This typically involves hardware malfunction, signal integrity loss, or unsafe probe state detection that prevents continued axis motion.
Siemens 840D 20106 - Emergency stop set by the digitizer
Emergency stop set by the digitizer
Siemens SINUMERIK 840D alarm 20106 indicates that an emergency stop was triggered by the digitizer (3D probe or digitizing system). The digitizing system has activated the emergency stop circuit.
Root Cause Summary
Alarm 20106 indicates the digitizing unit (probe/touch trigger sensor) has detected a critical fault condition and autonomously triggered an emergency stop via the NCK safety circuit. This typically involves hardware malfunction, signal integrity loss, or unsafe probe state detection that prevents continued axis motion.
Safety
Causes and Fixes
Verify physical probe connection at the probe head and control cabinet terminal block. Check MD 37000 (ProbeType) and MD 37010 (ProbeTouchSignalType) match the installed probe model in Diagnostics > Measuring Probe menu.
Do NOT bypass safety interlocks. Confirm E-stop is active before servicing probe hardware.
Test probe signal in NCK diagnostics: Navigate to Diagnostics > Inputs/Outputs > Probe Input (typically DI port assigned in MD 37100). Trigger probe mechanically and verify signal state change from 0 to 1 (or inverted logic per MD 37020).
If signal does not respond, measure continuity and voltage at probe connector using multimeter. Expected: 24V logic signal with <100ms response time. Check harness for pinch damage or moisture ingress.
Replace probe or harness assembly and re-initialize probe calibration via Diagnostics > Measuring Probe > Calibration. Clear alarm with soft reset (MDI: RESET) or hard reset if required.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.