Siemens 20083 - Axis programmed position lies behind the coordinate system-

Axis programmed position lies behind the coordinate system

The axis is traversed as a reciprocating axis, and the target position (reversal position or end position) is located behind the corresponding, valid, coordinate system-specific working area limitation. The axis is not traversed Control reaction: Local alarm reaction. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The axis is traversed as a reciprocating axis, and the target position (reversal position or end position) is located behind the corresponding, valid, coordinate system-specific working area limitation.
  • The axis is not traversed

Troubleshooting Steps

  1. 1Specify smaller target position.
  2. 2Deactivate working area limitation.
  3. 3Set working area limitation differentially.
  4. 4Clear alarm with the RESET key. Restart part program