Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisBasic10-20 minutes

16120

Siemens 16120 - Block invalid index for tool fine compensation

Block invalid index for tool fine compensation

Mistake in programming: The 2nd parameter in the PUTFTOC command indicates for which tool parameter the value is to be corrected (1 - 3 tool lengths, 4 tool radius). The programmed value is beyond the permitted range. Permissible values are 1 - 4 if on-line tool radius compensation is allowed (see MD20254 $MC_ONLINE_CUTCOM_ENABLE), otherwise values 1 - 3 Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Mistake in programming: The 2nd parameter in the PUTFTOC command indicates for which tool parameter the value is to be corrected (1 - 3 tool lengths, 4 tool radius).
  • The programmed value is beyond the permitted range.
  • Permissible values are 1 - 4 if on-line tool radius compensation is allowed (see MD20254 $MC_ONLINE_CUTCOM_ENABLE), otherwise values 1 - 3

Troubleshooting Steps

  1. 1Modify part program: Length 1 - 3 or 4 permissible for radius.
  2. 2Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.