Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

14415

Siemens 14415 - Block tangent control: changeover geometry/channel axis not

Block tangent control: changeover geometry/channel axis not

An assignment change of the geometry axes to channel axes is not permitted with active tangential control Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • An assignment change of the geometry axes to channel axes is not permitted with active tangential control

Troubleshooting Steps

  1. 1Change part program and delete active tangential control with TANGDEL.
  2. 2Clear alarm with NC START or RESET key and continue the program. Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.