14155

Siemens 14155 - Block invalid base frame definition for tool carrier offset

Block invalid base frame definition for tool carrier offset

If a tool carrier selection causes a change in the table offset, a valid base frame must be defined in order to store this offset; for more information see machine data 20184 (TOCARR_BASE_FRAME_NUMBER) Control reaction: Correction block is reorganized. Interpreter stop Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • If a tool carrier selection causes a change in the table offset, a valid base frame must be defined in order to store this offset; for more information see machine data 20184 (TOCARR_BASE_FRAME_NUMBER)

Troubleshooting Steps

  1. 1Change the NC program or machine data 20184 (TOCARR_BASE_FRAME_NUMBER).
  2. 2Clear alarm with NC START or RESET key and continue the program