Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

14170

Siemens 14170 - Block illegal interpolation type with tool length compensation

Block illegal interpolation type with tool length compensation

If tool compensation (G43/G44) is activated in language mode ISO_M, the linear type of interpolation must be active Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display. NC Stop on alarm at block end.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • If tool compensation (G43/G44) is activated in language mode ISO_M, the linear type of interpolation must be active

Troubleshooting Steps

  1. 1Modify part program.
  2. 2Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.