axismd.ai
Siemens SINUMERIK Controller
Program/G-code · Intermediate · 20-40 minutes
Siemens 14060 - Block invalid skip level with differential block skip
With "Differential block skip", a skip level greater than 7 has been specified. (In packet 1 specification of a value for the skip level is rejected by the converter as a syntax error, i.e. the only possibility is a "Suppress block" ON/OFF on one level) Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.
Siemens 14060 - Block invalid skip level with differential block skip
Block invalid skip level with differential block skip
With "Differential block skip", a skip level greater than 7 has been specified. (In packet 1 specification of a value for the skip level is rejected by the converter as a syntax error, i.e. the only possibility is a "Suppress block" ON/OFF on one level) Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.