Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-45 minutes

129933

Siemens 840D 129933 - DAT: The configured channel for part program in NCU is

DAT: The configured channel for part program in NCU is

The specified combination of NCU, part program and channel is invalid for time measuring of the configured workpiece. Remedy: Correct the corresponding entry in the DAT file belonging to the workpiece.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • DAT file channel assignment does not match the actual physical channel configuration in the NCU
  • Part program references a channel that does not exist or is not active in the current NCU setup
  • Mismatch between DAT file workpiece definition and the NCU/channel combination specified in the part program
  • DAT file contains incorrect syntax or formatting in the channel parameter definition
  • Channel configuration was modified in the NCU without corresponding update to the DAT file

Troubleshooting Steps

  1. 1Verify the physical channel configuration in the NCU matches the channel number specified in the DAT file for the referenced workpiece
  2. 2Cross-reference the part program name, NCU identifier, and channel number listed in the alarm message against the actual DAT file entries
  3. 3Check the DAT file syntax for the time measuring channel assignment; ensure proper formatting and valid channel references
  4. 4Confirm the NCU designation in the DAT file corresponds to the correct machine controller executing the part program
  5. 5Update the DAT file with the correct channel assignment and reload the workpiece configuration; re-run the part program to verify the alarm clears

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.