Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate20-40 minutes

12589

Siemens 840D 12589 - Channel block motion synchronous action: variable not

Channel block motion synchronous action: variable not

The modal ID in motion synchronous action must not be formed by means of an on-line variable. Examples: ID=$AC_MARKER[1] WHEN $a_in[1] == 1 DO $AC_MARKER[1] = $AC_MARKER[1]+1 This can be corrected in the following way: R10 = $AC_MARKER[1] ID=R10 WHEN $a_in[1] == 1 DO $AC_MARKER[1] = $AC_MARKER[1]+1

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • Modal ID in motion synchronous action defined directly using an online variable instead of intermediate register
  • Attempting to use $AC_MARKER array element directly in ID parameter without assignment to local variable first
  • Using input variable ($a_in) or other online variables directly in motion synchronous ID definition
  • Incorrect syntax in WHEN/DO clause referencing online variables for modal identification
  • Program structure attempting dynamic ID assignment that violates motion synchronous action constraints

Troubleshooting Steps

  1. 1Locate the motion synchronous action block in channel %1 at block %2 and identify the variable %3 being used in the ID parameter
  2. 2Review the syntax: if ID parameter directly references online variables like $AC_MARKER[], $a_in[], or similar, this is the root cause
  3. 3Replace direct online variable reference with intermediate register assignment - assign the online variable value to a local register (R-parameter) before the synchronous action block
  4. 4Update the ID parameter to reference the intermediate register instead of the online variable, maintaining the WHEN/DO clause logic unchanged
  5. 5Verify corrected syntax matches the pattern: R-register assignment, then ID=R-register reference, followed by WHEN/DO conditions

Seeing Multiple Alarms?