Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate20-45 minutes

10740

Siemens 10740 - Block too many empty blocks in WAB programming

Block too many empty blocks in WAB programming

It is not allowed to program more blocks than specified by MD20202 $MC_WAB_MAXNUM_DUMMY_BLOCKS between the WAB block and the block determining the approach and retraction tangent Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display. NC Stop on alarm at block end.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • It is not allowed to program more blocks than specified by MD20202 $MC_WAB_MAXNUM_DUMMY_BLOCKS between the WAB block and the block determining the approach and retraction tangent

Troubleshooting Steps

  1. 1Modify part program.
  2. 2Clear alarm with NC START or RESET key and continue the program. Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.