Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

101500

Siemens 840D 101500 - No other drives possible; option not set.

No other drives possible; option not set.

Siemens SINUMERIK alarm 101500: No other drives possible; option not set. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.

Root Cause Summary

Alarm 101500 occurs when attempting to activate or configure additional drive axes beyond the licensed capacity of the SINUMERIK 840D system. The NCK software detects that the hardware configuration or axis assignment exceeds what is permitted by the installed option licenses.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Navigate to HMI: Startup -> Service -> System Data -> License to check currently installed options and axis count.

  2. 2

    Compare licensed axis count with machine data MD10000 $MN_AXCONF_MACHAX_USED and MD10010 $MN_AXCONF_SPINDLE_USED to verify configuration matches license.

  3. 3

    If additional axes are required, contact Siemens to purchase and install appropriate license upgrade with extended axis option.

    Never attempt to modify license files manually - this will cause system failure.

  4. 4

    After license installation, perform NCK reset (Power Off -> On) and verify alarm clears during startup.

Service Recommended confidence