axismd.ai
Siemens SINUMERIK Controller
Program/G-code · Intermediate · 30-120 minutes
Siemens 840D 101213 - Invalid NCK address!
Alarm 101213 occurs when an invalid or out-of-range NCK (Numerical Control Kernel) bus address is specified during system configuration or commissioning. The address value exceeds the maximum allowable range defined by the SINUMERIK 840D architecture, typically during drive or axis configuration on the PROFIBUS or DRIVE-CLiQ network.
Siemens 840D 101213 - Invalid NCK address!
Invalid NCK address!
Siemens SINUMERIK message 101213: Invalid NCK address!. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.
Root Cause Summary
Alarm 101213 occurs when an invalid or out-of-range NCK (Numerical Control Kernel) bus address is specified during system configuration or commissioning. The address value exceeds the maximum allowable range defined by the SINUMERIK 840D architecture, typically during drive or axis configuration on the PROFIBUS or DRIVE-CLiQ network.
Safety
Causes and Fixes
Access HMI in Service mode and navigate to Commissioning -> HMI -> Service -> Machine Data.
Check MD30200 $MA_DRIVE_CTRLOUT_TYPE and MD30210 $MA_DRIVE_CTRLOUT_MODULE_NR for each axis to verify NCK addresses are within valid range.
Document current values before making changes.
Verify addresses against hardware configuration in HW Config (SIMATIC Manager) to ensure consistency between configured and actual drive addresses.
Correct any out-of-range values, perform NCK Reset (Power On with data backup), and re-reference axes.
Ensure machine is in safe state before NCK reset.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.