Program/G-code · Intermediate · 30-120 minutes
Siemens 840D 101169 - Date and time could not be set!
Alarm 101169 occurs when the SINUMERIK 840D system cannot write date and time settings to the NCK (Numerical Control Kernel) or system memory. This typically results from insufficient user rights, corrupted system files, failed battery backup causing persistent configuration loss, or filesystem errors preventing write operations to the system clock.
Siemens 840D 101169 - Date and time could not be set!
Date and time could not be set!
Siemens SINUMERIK operator message 101169: Date and time could not be set!. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.
Root Cause Summary
Alarm 101169 occurs when the SINUMERIK 840D system cannot write date and time settings to the NCK (Numerical Control Kernel) or system memory. This typically results from insufficient user rights, corrupted system files, failed battery backup causing persistent configuration loss, or filesystem errors preventing write operations to the system clock.
Safety
Causes and Fixes
Log out of the current HMI session and log in with manufacturer or service-level credentials (typically manufacturer password required).
Navigate to Startup -> NCU System Data -> General -> Date/Time and attempt to set the date and time again.
If successful, verify the settings persist after a complete power cycle (NCK and HMI).
Check user access level settings in the system configuration and adjust permissions if necessary for operational users.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.