Siemens SINUMERIK codes
Siemens SINUMERIKSafetyIntermediate30-120 minutes

101204

Siemens 840D 101204 - SI data not confirmed

SI data not confirmed

Siemens SINUMERIK message 101204: SI data not confirmed. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.

Root Cause Summary

Alarm 101204 indicates that Safety Integrated (SI) data changes have been made but not yet confirmed and activated. The safety system requires explicit acknowledgment before modified safety configuration data becomes active to prevent unauthorized or accidental safety parameter changes.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Safety Integrated commissioning interface on HMI or via STEP 7 Safety/Safety Integrated commissioning tool.

  2. 2

    Review pending SI configuration changes in the safety data comparison screen to verify all modifications are intentional.

    DO NOT confirm safety data unless you are authorized and have verified all changes are correct. Incorrect safety settings can cause machine hazards.

  3. 3

    Execute the Safety Acceptance Test procedure as required by your safety documentation to validate the new configuration.

    Safety acceptance tests must be performed according to machine manufacturer guidelines and local safety regulations.

  4. 4

    Confirm SI data using the acknowledgment function, enter required passwords, and perform a control restart to activate the new safety configuration.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.