Siemens SINUMERIK codes
Siemens SINUMERIKPLCIntermediate30-120 minutes

101017

Siemens 840D 101017 - No PLC input masks found !

No PLC input masks found !

Siemens SINUMERIK message 101017: No PLC input masks found!. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.

Root Cause Summary

Alarm 101017 indicates that the HMI/MMC system cannot locate the required PLC input mask files (*.plc) needed for operator panel operation. This typically occurs after a software installation, file system corruption, or when CompactFlash/CF card data has been lost or improperly restored.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Navigate to the HMI file system directory: /user/sinumerik/hmi/template or /addon/plc directory and verify if *.plc files exist.

  2. 2

    If files are missing, restore *.plc files from a known good backup to the correct HMI directory path.

    Ensure backup compatibility with current software version to avoid additional errors.

  3. 3

    If no backup available, re-commission the PLC masks using the original project files or HMI Advanced configuration tools.

  4. 4

    Perform a complete HMI restart (power cycle the MMC/HMI) and verify alarm clears and PLC screens are accessible.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.