HEIDENHAIN 330-005B - MC safety doors are open
HEIDENHAIN alarm 330-005B occurs when the TNC control detects open safety guard doors during axis safety self-test or brake test procedures. The SPLC (Safety PLC) interface prevents axis operations when PP_AxGrpStateReq signal is not in S_STATE_AUTO[10] state due to open door conditions.
HEIDENHAIN 330-005B - MC safety doors are open
MC safety doors are open
A PLC configuration or communication error has been detected. This affects the interaction between the control and the PLC system.
Root Cause Summary
HEIDENHAIN alarm 330-005B occurs when the TNC control detects open safety guard doors during axis safety self-test or brake test procedures. The SPLC (Safety PLC) interface prevents axis operations when PP_AxGrpStateReq signal is not in S_STATE_AUTO[10] state due to open door conditions.
Safety
Causes and Fixes
Visual door inspection
Check all machine guard doors are fully closed and latched. Verify door alignment with safety switch actuators.
Never bypass safety doors - serious injury risk
Check door switch engagement
Manually verify each door safety switch clicks when door closes. Listen for audible engagement of magnetic or mechanical switches.
Slight door adjustment may be needed if switches barely engage
Verify SPLC door status
Access TNC Setup menu → Machine Parameters → Safety Parameters to view door input status. All door inputs should show 'CLOSED' state.
Use MOD function to monitor real-time door input states
Call a technician if: