HEIDENHAIN 239-0024 - 24 UM-FSUC: cyclic communication overloaded CC

24 UM-FSUC: cyclic communication overloaded CC

This safety-related error indicates a fault in the FS microcontroller. The FS microcontroller has received too many cyclic telegrams. The control has detected a safety issue that may affect safe operation.

Root Cause Summary

Alarm 239-0024 indicates the FS (Field Service) microcontroller is overwhelmed by excessive cyclic communication telegrams on the CC (Communication Channel). This typically occurs when the TNC system is processing too many simultaneous communication requests from connected devices or when communication timing parameters are incorrectly configured.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check PLC cycle configuration

    Navigate to MOD function → PLC → Configuration and verify MP7300 (PLC cycle time). Increase from default 4ms to 8ms or 12ms if set too aggressively.

    Monitor actual PLC cycle time in the PLC status display - it should not exceed 80% of configured time

  2. 2

    Review connected I/O modules

    Access Setup → General → Control parameters → Communication and check MP120 series parameters for connected modules. Reduce unnecessary I/O polling frequency.

    Document current settings before making changes

  3. 3

    Optimize PLC program efficiency

    Review PLC.PRG for excessive marker usage or redundant I/O calls. Use PLC → Diagnostics → Cycle time to identify bottlenecks.

    Group I/O operations and avoid individual bit polling in tight loops

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hardware replacement needed for CC2 channel
  • ·Software version incompatibility requires update
  • ·Alarm persists after all diagnostic steps

Prevention

  • Regular monitoring of PLC cycle times and communication statistics
  • Proper cable management and shielding maintenance
  • Scheduled review of I/O configuration efficiency

Common Mistakes

  • Setting PLC cycle time too aggressively without considering I/O load
  • Ignoring communication error counters during routine maintenance
  • Adding I/O devices without reviewing total communication bandwidth