Heidenhain codes
HeidenhainCommunicationIntermediate30-120 minutes

235-0080

HEIDENHAIN 235-0080 - No password available for PLCE partition

No password available for PLCE partition

An existing PLCE partition cannot be integrated because the password cannot be read from the SIK or is not available from any other source.

Root Cause Summary

HEIDENHAIN alarm 235-0080 occurs when the TNC control cannot access the password required to integrate an existing PLCE partition, typically due to SIK (Software Installation Key) communication failure or corrupted security data. This prevents the PLC software from loading properly during system startup.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check SIK Physical Connection

    Verify the SIK is properly seated in the USB port or SIK slot on the TNC control unit.

    Power down the control before removing/inserting SIK

  2. 2

    Verify SIK Recognition

    Access MOD function → System → General → License Management to check if SIK is detected and shows valid license information.

    The SIK LED should show steady green when properly recognized

  3. 3

    Test Alternative SIK Port

    If multiple USB ports available, try connecting SIK to different port and restart control.

    Some TNC models have dedicated SIK slots that provide more reliable connection than USB ports

  4. 4

    Replace SIK Hardware

    If SIK still not recognized, contact Heidenhain for SIK replacement with same license configuration.

Service Recommendedmedium confidence

Call a technician if:

  • ·SIK replacement required
  • ·Software version updates needed
  • ·Partition rebuild fails
  • ·No backup available

Prevention

  • Regular SIK backup and replacement schedule
  • Maintain current software backups with PLCE partitions
  • Monitor SIK LED status during routine maintenance
  • Document PLCE configuration changes

Common Mistakes

  • Attempting partition recovery without backup
  • Ignoring SIK hardware degradation signs
  • Mixing TNC software versions with existing PLCE partitions
  • Not verifying machine parameters after software updates