235-0070

HEIDENHAIN 235-0070 - Incorrect format version of the IOC file

Incorrect format version of the IOC file

The IOC file has an incorrect format version that cannot be processed by the control. Different bus types require specific minimum IOC file versions.

Root Cause Summary

HEIDENHAIN alarm 235-0070 occurs when the IOC (Input/Output Configuration) file format version is incompatible with the fieldbus protocol being used. The TNC control requires specific minimum IOC format versions for different communication protocols (PROFIBUS/AS-i: V2, HSCI: V3, PROFINET: V4).

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access PLC configuration menu

    Navigate to MOD > PLC > Configuration > I/O Configuration to check current IOC file version and fieldbus settings.

    Check the file header information which displays the IOC format version

  2. 2

    Verify PROFINET configuration requirements

    Confirm PROFINET is configured in machine parameter MP7600 (fieldbus type) and verify IOC file shows V4 format in file properties.

    Changing fieldbus parameters requires machine restart and may affect all I/O operations

  3. 3

    Update IOC file to V4 format

    Use TNCopt or latest version of IOC configuration software to regenerate the IOC file in V4 format for PROFINET compatibility.

    Always backup the working IOC file before making changes

  4. 4

    Load updated IOC configuration

    Transfer the new V4 IOC file via TNCopt or CF card to TNC:\PLC\IOC\ directory and restart the control.

    Ensure all connected PROFINET devices are powered and accessible before restart

DIY Feasiblehigh confidence

Call a technician if:

  • ·IOC regeneration fails repeatedly
  • ·Fieldbus hardware compatibility issues
  • ·Multiple related communication alarms persist

Prevention

  • Always verify IOC format version matches fieldbus requirements before loading
  • Keep backup copies of working IOC files
  • Document IOC file versions with TNC software updates
  • Use latest HEIDENHAIN configuration tools for IOC generation

Common Mistakes

  • Loading PROFIBUS IOC file when PROFINET is configured
  • Using outdated IOC configuration software
  • Not checking fieldbus type in machine parameters before IOC creation
  • Mixing IOC format versions in multi-protocol installations

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.