Heidenhain Controller
Communication · Intermediate · 30-120 minutes
HEIDENHAIN 234-0001 - Insufficient memory
HEIDENHAIN alarm 234-0001 occurs when the TNC control's Ethernet communication system has exceeded its maximum client connection limit. This typically happens when too many network devices or software applications are simultaneously attempting to establish connections to the control's Ethernet interface.
HEIDENHAIN 234-0001 - Insufficient memory
Insufficient memory
This TNC7/TNC 640 system error indicates Too many clients are configured for the Ethernet transmis- sion. The control has detected an abnormal state that requires attention.
Root Cause Summary
HEIDENHAIN alarm 234-0001 occurs when the TNC control's Ethernet communication system has exceeded its maximum client connection limit. This typically happens when too many network devices or software applications are simultaneously attempting to establish connections to the control's Ethernet interface.
Safety
Causes and Fixes
Check active DNC connections
Press MOD key, select 'Communication' menu, then 'Ethernet' to view current active client connections and their status.
Look for duplicate or orphaned connections from the same IP address
Verify MP7210 parameter setting
Access machine parameters via MOD key, navigate to MP7210 (Max. number of Ethernet clients) and check if the value is appropriate for your network setup.
Changing this parameter requires control restart and may affect network performance
Disconnect unnecessary clients
Close unused DNC software, CAM applications, or remote monitoring tools that may be maintaining open connections to the TNC control.
Use 'netstat' command on connected PCs to identify active connections to the control's IP address
Reset Ethernet communication
In MOD menu under 'Communication' > 'Ethernet', select 'Reset Ethernet' to clear all active connections and allow fresh connections.
This will disconnect all current network communications temporarily
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.