System · Intermediate · 30-120 minutes
HEIDENHAIN 231-8B30 - 8B30 Motor temp. too high
Alarm 231-8B30 indicates the motor temperature monitoring system has detected an overtemperature condition or a failure in the temperature sensing circuit. This alarm fires when the TNC control receives either an actual high temperature signal from the motor's thermal sensor or detects a fault in the temperature monitoring chain including sensor, wiring, or parameter configuration.
HEIDENHAIN 231-8B30 - 8B30 Motor temp. too high
8B30 Motor temp. too high
This TNC 640 error indicates an internal control fault. The issue relates to Measured motor temperature is too high.
Root Cause Summary
Alarm 231-8B30 indicates the motor temperature monitoring system has detected an overtemperature condition or a failure in the temperature sensing circuit. This alarm fires when the TNC control receives either an actual high temperature signal from the motor's thermal sensor or detects a fault in the temperature monitoring chain including sensor, wiring, or parameter configuration.
Safety
Causes and Fixes
Check Cable Continuity
Disconnect motor encoder cable and measure continuity of temperature sensor wires (typically pins for PT100/PT1000 sensor) using multimeter.
Ensure axis power is OFF before disconnecting encoder cables
Inspect Cable for Physical Damage
Examine encoder cable along its entire length for kinks, cuts, or damage especially at cable chain entry/exit points and motor connection.
Flex the cable while measuring continuity to detect intermittent breaks
Verify Connector Pin Contact
Clean and inspect encoder connector pins at both motor and control cabinet ends, ensure proper seating and no corrosion on temperature sensor pins.
Replace Encoder Cable
If continuity test fails or physical damage found, replace complete motor encoder cable with Heidenhain specified part number.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.