Heidenhain codes
HeidenhainSystemIntermediate30-120 minutes

231-8B10

HEIDENHAIN 231-8B10 - 8B10 Wrong traverse direction

8B10 Wrong traverse direction

This TNC 640 error indicates an internal control fault. The issue relates to DIR entry in motor table is incorrect.

Root Cause Summary

Alarm 231-8B10 occurs when the TNC control detects that an axis is moving in the opposite direction to the commanded movement. This typically results from incorrect DIR parameter settings in the motor configuration table or reversed motor power connections causing phase sequence issues.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Motor Configuration

    Press MOT key, then select the affected axis from the motor table display.

    Always note the current DIR value before making changes for easy rollback.

  2. 2

    Check DIR Parameter

    Locate the DIR parameter for the affected axis. Value should be 0 or 1 depending on motor wiring configuration.

    Ensure machine is in safe position before testing direction changes.

  3. 3

    Toggle DIR Setting

    Change DIR from 0 to 1 or 1 to 0, then save the parameter change and cycle power to the control.

    Test with small incremental moves (0.1mm) before full operation.

  4. 4

    Verify Correction

    Execute small positive and negative moves in MDI mode to confirm direction correspondence matches commanded direction.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Multiple axes affected simultaneously
  • ·Encoder replacement required
  • ·Drive amplifier hardware failure suspected

Prevention

  • Document all motor and encoder wiring during installation
  • Verify direction settings during commissioning
  • Use consistent phase rotation throughout facility

Common Mistakes

  • Changing both TNC DIR and drive direction simultaneously
  • Not cycling power after parameter changes
  • Testing with rapid movements instead of incremental moves