HEIDENHAIN 230-0460 - Error in configuration of axis
This alarm is triggered by the TNC control's internal parameter validation routines detecting logical inconsistencies within an axis configuration. The control performs comprehensive cross-checking of interdependent parameters during initialization, and this alarm prevents operation when the axis configuration does not meet the required logical framework for safe and proper machine operation.
HEIDENHAIN 230-0460 - Error in configuration of axis
Error in configuration of axis
The axis configuration contains errors in power supply or motor settings. Incorrect parameters for supply module, power stage, or motor supply may be present.
Root Cause Summary
This alarm is triggered by the TNC control's internal parameter validation routines detecting logical inconsistencies within an axis configuration. The control performs comprehensive cross-checking of interdependent parameters during initialization, and this alarm prevents operation when the axis configuration does not meet the required logical framework for safe and proper machine operation.
Safety
Causes and Fixes
Access Machine Parameters
Press MOD key, enter machine parameter mode (requires keyswitch position 2 or password depending on TNC model), navigate to General → CfgAxes → Axis [affected axis]
Working in machine parameters requires proper authorization and documentation. Incorrect changes can damage machine or control.
Verify MP100 Axis Type
Check MP100 for the affected axis. Valid values: 0=not used, 1=linear axis, 2=rotary axis display ±180°, 3=rotary axis display 0-360°, 4=modulo axis. Ensure value matches physical axis configuration.
Cross-reference with MP110 (axis designation) to ensure logical consistency between axis type and its assigned letter (X/Y/Z for linear, A/B/C for rotary).
Validate Dependent Parameters
After confirming MP100, verify MP101-109 (display resolution, monitoring windows) and MP200-202 (software limit switches) are appropriate for the defined axis type.
Linear axes require software limits in MP200/201, while modulo axes (MP100=4) should have these set to 0 or undefined.
Restart Control and Test
Save all parameter changes, perform a complete control restart (power cycle), and verify the axis configuration loads without alarm during POST sequence.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.