Heidenhain codes
HeidenhainServo/AxisIntermediate30-120 minutes

230-0450

Heidenhain 230-0450 - Axis: Enter CfgReferencing/doubleRefOffset:

Axis: Enter CfgReferencing/doubleRefOffset

Heidenhain TNC error 230-0450: Axis: Enter CfgReferencing/doubleRefOffset. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

Alarm 230-0450 occurs when the TNC control detects that a reference run has been executed twice on the same axis without proper acknowledgment or parameter configuration. The system requires the CfgReferencing/doubleRefOffset parameter to be properly configured to handle multiple reference runs.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access machine parameter configuration

    Press MOD key, select 'Machine Parameters', navigate to CfgReferencing section using parameter search function.

    Use Ctrl+F to quickly search for 'doubleRefOffset' parameter

  2. 2

    Verify doubleRefOffset parameter

    Check if CfgReferencing/doubleRefOffset parameter exists and has a valid numerical value for the affected axis.

    Parameter changes require machine manufacturer authorization

  3. 3

    Configure parameter value

    Set doubleRefOffset to appropriate value based on encoder resolution and machine specifications, typically 0.001-0.01mm.

    Consult machine documentation for manufacturer-recommended offset values

  4. 4

    Save and restart control

    Save parameter changes and perform control restart to activate new configuration before attempting reference run.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Parameter modification rights not available
  • ·Encoder hardware replacement needed
  • ·Drive amplifier configuration required

Prevention

  • Always complete reference runs fully before starting new operations
  • Regularly verify encoder signal quality
  • Maintain clean encoder scales and proper cable routing

Common Mistakes

  • Interrupting reference runs mid-cycle
  • Ignoring encoder signal quality warnings
  • Modifying reference parameters without understanding machine geometry

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.