FANUC Robot codes
FANUC RobotServo/AxisIntermediate15-60 minutes

SRVO-037

Fanuc Robot SRVO-037 - IMSTP input

IMSTP input

The *IMSTP (Immediate Stop) peripheral device input signal is OFF. This is a hardware immediate stop signal from an external device that requires immediate shutdown of robot motion.

Root Cause Summary

SRVO-037 IMSTP input alarm occurs when the *IMSTP (Immediate Stop) hardware signal is not in its expected active state. This is a hardwired safety interlock signal that requires the external device or PLC to actively enable the robot by holding this signal in the correct state. The alarm prevents robot motion until the external immediate stop condition is cleared and the signal returns to its normal operating state.

Safety

  • Always verify robot is in a safe stopped state before entering the work envelope
  • Use T1 (low speed) mode when testing after clearing motion or servo alarms

Causes and Fixes

  1. 1

    Check external equipment status

    Inspect all connected equipment, PLCs, and safety devices for active alarms, E-stop buttons pressed, safety gates open, light curtains blocked, or any fault indicators. Check operator panel displays and PLC HMI screens for fault messages.

    Do not bypass or jumper safety devices. Resolve the actual safety condition before proceeding.

  2. 2

    Verify PLC logic and outputs

    Access the PLC program and monitor the output coil driving the *IMSTP signal to the robot. Verify the logic conditions required to enable this output are all satisfied. Check for latched fault bits or timers preventing the signal from activating.

    Many integrators use a 'first fault capture' or alarm stack in the PLC. Check if an earlier transient fault is still latched even though the immediate condition cleared.

  3. 3

    Monitor IMSTP signal status in real-time

    On the teach pendant, navigate to MENU → I/O → Digital → Check the *IMSTP signal assignment (typically UI[1] or similar system input). Watch this signal while clearing external faults to confirm it changes state. Press [SHIFT]+[COORD] to view I/O in real-time diagnostic mode.

    The *IMSTP signal should show ON (1) during normal operation. If it shows OFF (0), the external device is actively stopping the robot.

  4. 4

    Clear the alarm after signal restoration

    Once the external device resolves its fault and the *IMSTP signal shows active (ON) in the I/O diagnostics, press and hold RESET on the teach pendant for 2 seconds. The SRVO-037 alarm should clear if the signal remains stable.

    If the alarm immediately returns after reset, the external signal is unstable or the fault condition is still present.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.