Fanuc Robot SRVO-015 - System over heat

System over heat

The controller internal temperature has exceeded the specified limit. The robot will stop within approximately one minute if the temperature is not reduced. This alarm indicates a cooling system failure or excessive ambient temperature.

Root Cause Summary

SRVO-015 System Over Heat alarm occurs when the R-30iA/R-30iB controller's internal temperature exceeds the critical threshold of 55-60°C, triggering thermal protection circuits. This alarm gives approximately 60 seconds warning before automatic emergency stop (E-STOP) to prevent permanent damage to servo amplifiers, CPU boards, and power supply components. The most common causes are obstructed airflow due to clogged filters or failed cooling fans, followed by excessive ambient temperatures in the controller environment.

Safety

  • Always verify robot is in a safe stopped state before entering the work envelope
  • Use T1 (low speed) mode when testing after clearing motion or servo alarms

Causes and Fixes

  1. 1

    Inspect and Replace Air Filter

    Open the lower front panel of the controller cabinet and remove the air filter assembly. The filter should be white or light gray; if it appears dark gray or black, it requires immediate replacement. R-30iA/R-30iB use Fanuc part number A05B-0235-C003 (standard filter). Replace every 3-6 months in normal environments, monthly in high-dust applications.

    Keep spare filters on-site. In emergency situations, you can temporarily vacuum the existing filter to restore partial airflow, but replace it within 24 hours. Never run the controller without a filter as dust will accumulate on servo amplifier heat sinks.

  2. 2

    Check Ventilation Clearance

    Verify minimum clearance requirements: 300mm (12 inches) on all ventilated sides of the cabinet, 500mm (20 inches) at the rear where exhaust fans are located. Remove any materials, tooling, or equipment stored against the cabinet. Check that cable management has not blocked bottom intake vents.

    Never stack materials on top of the controller cabinet or block rear exhaust fans. This can cause overheating within 15-30 minutes of operation under load.

  3. 3

    Inspect Internal Airflow Path

    With the controller powered down and locked out, open the front cabinet door and visually inspect the internal airflow path from bottom intake through the servo amplifier stack to top exhaust. Remove any accumulated dust or debris using compressed air (maximum 40 PSI) or a vacuum. Pay special attention to heat sink fins on servo amplifiers.

    Always follow lockout/tagout procedures before opening the controller cabinet. Discharge capacitors may retain lethal voltage for up to 5 minutes after power removal. Wait at least 10 minutes and verify zero voltage before internal work.

  4. 4

    Verify Servo Amplifier Heat Sink Condition

    Examine the heat sink fins on each servo amplifier module. Dust buildup reduces thermal transfer efficiency by 40-60%. Use compressed air to blow out dust between fins, directing airflow from top to bottom to match normal cooling direction. If fins are corroded or damaged, the amplifier requires replacement.

    Document the cleanliness state with photos. Establish a preventive maintenance schedule based on your environment: clean heat sinks every 6 months in climate-controlled areas, every 3 months in industrial environments with machining operations nearby.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.