FANUC codes
FANUCProgram/G-codeIntermediate5-30 minutes

331

Fanuc 331 - Illegal command in peck drilling

ILLEGAL COMMAND IN PECK DRILLING

Fanuc PS program alarm 331: ILLEGAL COMMAND IN PECK DRILLING. This alarm is triggered by an illegal or incorrectly formatted command in the part program, or a programming condition that the Fanuc control cannot execute.

Root Cause Summary

Alarm 331 occurs when the control detects an improper command or parameter within a canned cycle peck drilling operation (G73, G83, or G87). This typically results from missing required parameters, conflicting modal commands, or illegal G-code combinations that violate the peck drilling cycle execution rules.

Safety

  • Verify corrected program or parameters before resuming machining

Causes and Fixes

  1. 1

    Locate the alarm line number in the program and identify the G83 or G73 block causing the alarm.

  2. 2

    Verify Q value (peck increment) is present and is a positive non-zero value. Check that R-plane is above the Z-depth value.

  3. 3

    Confirm all required addresses are present: X, Y (or one axis for single-axis drilling), Z (final depth), R (retract/reference plane), Q (peck depth), and F (feedrate).

  4. 4

    Correct the missing or invalid parameters, ensure R > Z in negative Z drilling (R-plane must be above final depth), then reset alarm and test cycle.

Service Recommended confidence