Siemens 840D 62318 - Channel Block: Tolerance of the rotary axis vector exceeded
Alarm 62318 is triggered during CYCLE996 execution when the rotary axis vector tolerance threshold is violated, indicating the programmed rotary axis position deviates beyond the acceptable tolerance band defined in the machine data. This typically occurs in 5-axis simultaneous interpolation or spatial rotation cycles where rotary axis synchronization with linear axes is critical.
Siemens 840D 62318 - Channel Block: Tolerance of the rotary axis vector exceeded
Channel Block: Tolerance of the rotary axis vector exceeded
Siemens SINUMERIK alarm 62318: Channel Block: Tolerance of the rotary axis vector exceeded. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 62318 is triggered during CYCLE996 execution when the rotary axis vector tolerance threshold is violated, indicating the programmed rotary axis position deviates beyond the acceptable tolerance band defined in the machine data. This typically occurs in 5-axis simultaneous interpolation or spatial rotation cycles where rotary axis synchronization with linear axes is critical.
Safety
Causes and Fixes
Access Diagnostics > Machine Data > Axis-Specific > Check MD33300 (tolerance value in degrees or mm). Compare current setting to factory defaults documented in the machine manual. Typical range: 0.1° to 1.0° for rotary axes.
Do not modify MD parameters while cycle execution is in progress; stop the program first.
Monitor actual vs. commanded rotary axis position in Diagnostics > Real-time Values > Axis Status. During CYCLE996 replay, observe the deviation magnitude to determine if tolerance is physically achievable with current servo gains.
Increase MD33300 / MD33301 incrementally by 0.05° intervals and retry CYCLE996. If alarm clears, servo performance is adequate but tolerance was too tight. If alarm persists, proceed to next cause block.