Siemens 61807 - Block : Wrong spindle direction programmed (active)
Alarm 61807 occurs when the spindle direction command in the NC program contradicts the spindle direction requirement embedded in CYCLE840 execution. This conflict arises from explicit M-code spindle commands (M3/M4/M5) that override or conflict with the cycle's internally-planned spindle direction, which is determined by the cycle's direction parameter and related machine configuration.
Siemens 61807 - Block : Wrong spindle direction programmed (active)
Block: Wrong spindle direction programmed (active)
The programmed spindle direction contradicts the spindle direction planned for the cycle Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.
Root Cause Summary
Alarm 61807 occurs when the spindle direction command in the NC program contradicts the spindle direction requirement embedded in CYCLE840 execution. This conflict arises from explicit M-code spindle commands (M3/M4/M5) that override or conflict with the cycle's internally-planned spindle direction, which is determined by the cycle's direction parameter and related machine configuration.
Safety
Causes and Fixes
Review the CYCLE840 call in the NC program block identified in alarm parameter %2. Check the direction parameter (typically 3rd or 4th parameter) of the cycle invocation.
Verify the M-code spindle commands (M3/M4/M5) immediately before or within the CYCLE840 block. Compare against the cycle's required direction: if CYCLE840 expects CCW (direction = -1 or equivalent) but M3 (CW) is active, the conflict occurs.
Check program sequence—M-codes executed in the same or preceding block may still be active when cycle executes.
Modify the NC program to remove conflicting M-codes or adjust the CYCLE840 direction parameter to match the spindle direction already commanded. Ensure spindle direction is either undefined (M5 active) or matches the cycle requirement before CYCLE840 execution.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.