Siemens 16772 - Block axis is the slave axis, the coupling is being opened
This alarm occurs when an axis is active as a slave in a coupling during REF operation mode, causing the coupling to open. It can be resolved by adjusting the program or suppressing the alarm via machine data.
Siemens 16772 - Block axis is the slave axis, the coupling is being opened
Block axis is the slave axis, the coupling is being opened
The axis is active as a following axis in a coupling. In REF operating mode, the coupling is opened. The alarm can be suppressed with MD11410 $MN_SUPPRESS_ALARM_MASK bit 29 = 1 or with CP programming by setting CPMALARM[FAx] bit 0 = 1 Control reaction: Alarm display.
Root Cause Summary
This alarm occurs when an axis is active as a slave in a coupling during REF operation mode, causing the coupling to open. It can be resolved by adjusting the program or suppressing the alarm via machine data.
Safety
Causes and Fixes
SAFETY: Lock out machine and consult documentation
Ensure machine is in safe state before diagnostics. Review Siemens documentation for your specific controller version.
Check program mode
Verify if the program is running in REF operation mode at the alarmed block.
Adjust program (technician recommended)
Modify the program to avoid coupling operations in REF mode if possible. Consult technician for complex coupling scenarios.
Suppress alarm (technician only)
TECHNICIAN ONLY: Set machine data 11410 SUPPRESS_ALARM_MASK Bit29 = 1 only after confirming safety implications.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.