Siemens SINUMERIKServo/AxisIntermediate30-60 minutes

14541

Siemens 14541 - Block contour tool: the max. limit angle has been programmed more

Block contour tool: the max. limit angle has been programmed more

The limit angle of a contour tool must be equal zero in an involved edge only Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display. NC Stop on alarm at block end.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The limit angle of a contour tool must be equal zero in an involved edge only

Troubleshooting Steps

  1. 1Change tool definition.
  2. 2Clear alarm with NC START or RESET key and continue the program