Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate20-40 minutes

14116

Siemens 14116 - Block absolute orientation programmed while ORIPATH/ORIPATHS

Block absolute orientation programmed while ORIPATH/ORIPATHS

The orientation has been entered as an absolute value (e.g. by a direction vector or a rotation vector), although ORIPATH or ORIPATHS are active. When ORIPATH/ORIPATHS is active, the orientation is determined from the lead angle, tilt angle and angle of rotation relative to the path tangent and surface normal vector Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The orientation has been entered as an absolute value (e.g. by a direction vector or a rotation vector), although ORIPATH or ORIPATHS are active.
  • When ORIPATH/ORIPATHS is active, the orientation is determined from the lead angle, tilt angle and angle of rotation relative to the path tangent and surface normal vector

Troubleshooting Steps

  1. 1Modify part program.
  2. 2Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.