Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

12730

Siemens 12730 - Block no valid transformation machine data parameterized

Block no valid transformation machine data parameterized

The machine data MD24100 $MC_TRAFO_TYPE_1, MD24110 $MC_TRAFO_AXES_IN_1[1], MD24210 $MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1 Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The machine data MD24100 $MC_TRAFO_TYPE_1, MD24110 $MC_TRAFO_AXES_IN_1[1], MD24210 $MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1

Troubleshooting Steps

  1. 1Enter valid transformation identifier for TRACYL in MD24100 $MC_TRAFO_TYPE_1 and the rotary axis number in MD24110 $MC_TRAFO_AXES_IN_1[1] or MD24210 $MC_TRAFO_AXES_IN_2[1].
  2. 2Alarms NCK alarms
  3. 3Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.