12210

Siemens 840D 12210 - Channel block string too long

Channel block string too long

- In the definition of a variable of type STRING, it has been attempted to initialize more than 100 characters. - In an allocation, it has been found that the string does not fit in the given variable.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Common Causes

  • STRING variable initialized with more than 100 characters in source code
  • Attempted assignment of a string longer than 100 characters to a STRING type variable
  • Incorrect variable declaration size in part program or custom macro
  • String literal or concatenation result exceeds 100 character limit for STRING type

Troubleshooting Steps

  1. 1Locate the referenced block number %2 in the part program and identify the STRING variable declaration or assignment on line %3
  2. 2Check the actual character count of the string value being assigned; count characters including spaces and special characters
  3. 3If string exceeds 100 characters, either split into multiple STRING variables, use CHAR array type, or reduce the string content length
  4. 4Verify variable declaration syntax matches Siemens 840D/828D STRING format and that no unintended characters were copied into the program
  5. 5Clear the alarm, reload the corrected program, and verify syntax using the CNC editor's program check function before resuming execution