Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

104118

Siemens 840D 104118 - PA: Error on reading JOG feed

PA: Error on reading JOG feed

Siemens SINUMERIK alarm 104118: PA: Error on reading JOG feed. This alarm indicates an error condition in the NC program or control configuration that must be resolved before the operation can continue.

Root Cause Summary

Alarm 104118 indicates the control system cannot properly read or interpret the JOG feed rate parameters during manual jogging operations. This typically occurs due to corrupted or invalid JOG-related machine data (MD), incorrect parameter settings in the initialization files, or problems with the control's axis configuration that prevent proper feed rate calculation.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Service Mode and navigate to Settings > Machine Data. Check JOG-related MDs: MD11700-11730 (JOG increment data) and MD14000-14020 (JOG feedrate data) for all active axes.

  2. 2

    Verify JOG feedrate values are within valid range (typically 0.001 to maximum axis velocity). Check MD14001 $MN_JOG_VELO_RAPID and MD14002 $MN_JOG_VELO for reasonable values.

  3. 3

    If values are corrupted or show as zero/invalid, restore default JOG machine data from a known good backup or reload from commissioning files.

    Ensure you have a complete backup before modifying machine data.

  4. 4

    Perform a POWER ON reset (Warm Start) to reinitialize the control with corrected machine data. Test JOG operation on each axis.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.