Siemens 840D 104025 - No magazine configured
Alarm 104025 occurs when the NC program or manual operation attempts to execute a tool change or magazine-related command, but the system configuration does not have a tool magazine defined. This is typically a configuration mismatch between the part program expectations and the actual machine setup in the system data.
Siemens 840D 104025 - No magazine configured
No magazine configured
Siemens SINUMERIK message 104025: No magazine configured. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.
Root Cause Summary
Alarm 104025 occurs when the NC program or manual operation attempts to execute a tool change or magazine-related command, but the system configuration does not have a tool magazine defined. This is typically a configuration mismatch between the part program expectations and the actual machine setup in the system data.
Safety
Causes and Fixes
Access Service mode and navigate to Setting Data: Check MD18090 $MN_MM_NUM_MAGAZINE (number of magazines). Verify it is set to at least 1 if a magazine exists.
Requires service access level and password
Check MD18110 $MN_MM_TYPE_OF_MAGAZINE[n] for magazine type definition (linear, chain, matrix, etc.). Ensure proper type is configured for your tool magazine.
Verify MD18120 $MN_MM_NUM_LOCATION[n] defines the correct number of tool pockets/locations in the magazine.
After making changes, perform a complete power cycle (NCK Reset) and verify configuration is active.
Document original settings before making changes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.