Siemens 840D 104005 - There is no active cutting edge

There is no active cutting edge

Siemens SINUMERIK message 104005: There is no active cutting edge. This is an operator information message from the SINUMERIK control. Note the complete message text as it may contain important parameter values.

Root Cause Summary

Alarm 104005 occurs when the control system detects that no cutting edge has been activated for the currently selected tool. This typically happens when a tool is called but the D-number (cutting edge offset) has not been programmed or is set to zero, meaning the tool geometry is undefined for machining operations.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Review the NC program at the line where the alarm occurred and identify the tool call (T-word).

  2. 2

    Check if a D-word is programmed after the T-word (e.g., T1 D1). If missing or D0, add the appropriate D-number corresponding to the cutting edge.

  3. 3

    Verify that the D-number corresponds to an existing offset in the tool offset table for that tool number.

  4. 4

    Reload and restart the program from a safe position to confirm the alarm is cleared.

Service Recommended confidence