Siemens 840D 103013 - No agreement could be given
Alarm 103013 occurs when the control system cannot obtain required agreement or confirmation from a necessary component, typically during configuration changes, safety circuit verification, or PLC handshake processes. This alarm indicates a communication breakdown or missing acknowledgment between the NCK (Numerical Control Kernel) and other system components such as PLC, HMI, or safety modules.
Siemens 840D 103013 - No agreement could be given
No agreement could be given
Siemens SINUMERIK alarm 103013: No agreement could be given. This alarm indicates a required configuration element, parameter, or program component is missing or has not been set up.
Root Cause Summary
Alarm 103013 occurs when the control system cannot obtain required agreement or confirmation from a necessary component, typically during configuration changes, safety circuit verification, or PLC handshake processes. This alarm indicates a communication breakdown or missing acknowledgment between the NCK (Numerical Control Kernel) and other system components such as PLC, HMI, or safety modules.
Safety
Causes and Fixes
Check PLC status on the HMI under Diagnostics > PLC. Verify that the PLC is in RUN mode and not in STOP or error state.
Review the alarm buffer for preceding PLC alarms (61000-62999 range) that may indicate why the PLC cannot provide agreement.
Access PLC diagnostics and monitor the interface signals DB19 and DB21. Check for stuck bits or signals that should toggle but remain static.
Document current signal states before making changes for comparison.
Verify PLC program logic for acknowledgment signals related to mode changes, axis enable requests, or configuration changes. Look for missing RESET conditions or timeout logic errors.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.