axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Basic · 5-15 minutes
Siemens 840D 103004 - Block search not possible
Alarm 103004 occurs when attempting to initiate a block search operation while the NC channel is still actively executing a program or in an operational state. The control system prevents block search during active channel states to avoid conflicts and ensure safe positioning integrity.
Siemens 840D 103004 - Block search not possible
Block search not possible
The search run cannot be started because the channel is active. Remedy: Wait until the program has been executed or trigger an NC reset.
Root Cause Summary
Alarm 103004 occurs when attempting to initiate a block search operation while the NC channel is still actively executing a program or in an operational state. The control system prevents block search during active channel states to avoid conflicts and ensure safe positioning integrity.
Safety
Causes and Fixes
Check the NC display to verify current program status - look for ACTIVE, INTERRUPTED, or STOP indicators in the channel state bar.
If program is running or paused, press NC STOP to halt execution completely. Wait for channel status to show RESET or IDLE.
Press RESET button on the machine control panel to clear the channel and reset the NC kernel to idle state.
Ensure all axes are in a safe position before issuing NC RESET as it will cancel all active movements.
Verify channel status shows RESET, then re-attempt the block search operation from the desired program line.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.