Siemens SINUMERIK alarm 10256: [up to SW 3.x only] Channel reorg sequence canceled. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.

Root Cause Summary

Alarm 10256 occurs when a reorganization sequence in the specified channel is interrupted or canceled during execution on SW 3.x or earlier systems. This typically happens when the control system detects an irregular condition during memory reorganization, such as user intervention, motion interruption, or internal processing conflicts that prevent the reorg from completing normally.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check the alarm log timestamp and correlate with operator actions - verify if RESET or STOP was pressed during program execution.

  2. 2

    Review the part program for REORG or repositioning commands and identify where the interruption occurred.

  3. 3

    Clear the alarm using the CLEAR key and verify channel status shows RESET condition.

  4. 4

    Restart the program from a safe position or beginning of block. Train operators to avoid interrupting repositioning sequences.

    Ensure machine is in a safe position before restarting to avoid collisions.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.