10241

Siemens 10241 - [up to SW 3.x only] Mode group mode change in active channel

[up to SW 3.x only] Mode group mode change in active channel

The channel is not in the stopped state. Reorganization is therefore impossible Control reaction: Alarm display.

Root Cause Summary

Alarm 10241 occurs when an operator attempts to change the mode group (JOG, MDA, AUTO) while a channel is still actively executing a program or motion. This is a programming/operational error specific to SW 3.x and earlier versions where mode changes were more restrictive during active channel operations.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Press the RESET button to acknowledge and clear the alarm.

  2. 2

    Wait for the active channel to complete its current operation or press the feed hold/stop button to safely halt program execution.

  3. 3

    Verify the channel status shows READY or IDLE before attempting the mode change again.

  4. 4

    Perform the desired mode group change once the channel is inactive.