Siemens SINUMERIK Controller
Program/G-code · Intermediate · 30-120 minutes
Siemens 10241 - [up to SW 3.x only] Mode group mode change in active channel
Alarm 10241 occurs when an operator attempts to change the mode group (JOG, MDA, AUTO) while a channel is still actively executing a program or motion. This is a programming/operational error specific to SW 3.x and earlier versions where mode changes were more restrictive during active channel operations.
Siemens 10241 - [up to SW 3.x only] Mode group mode change in active channel
[up to SW 3.x only] Mode group mode change in active channel
The channel is not in the stopped state. Reorganization is therefore impossible Control reaction: Alarm display.
Root Cause Summary
Alarm 10241 occurs when an operator attempts to change the mode group (JOG, MDA, AUTO) while a channel is still actively executing a program or motion. This is a programming/operational error specific to SW 3.x and earlier versions where mode changes were more restrictive during active channel operations.
Safety
Causes and Fixes
Press the RESET button to acknowledge and clear the alarm.
Wait for the active channel to complete its current operation or press the feed hold/stop button to safely halt program execution.
Verify the channel status shows READY or IDLE before attempting the mode change again.
Perform the desired mode group change once the channel is inactive.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.