Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

101145

Siemens 840D 101145 - MD1104/1118

MD1104/1118

Siemens SINUMERIK operator message 101145: MD1104/1118. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

Alarm 101145 indicates an inconsistency or invalid configuration in machine data MD1104 (AXCONF_MACHAX_NAME_TAB) or MD1118 (AXCONF_GEOAX_NAME_TAB), which define the machine axis and geometry axis names respectively. This typically occurs when axis naming conventions are violated, duplicate names exist, or there's a mismatch between configured axes and their actual assignments in the system.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Enter commissioning mode and navigate to Settings → Machine Data → Channel-specific MD → Basic Machine → MD1104 (AXCONF_MACHAX_NAME_TAB).

  2. 2

    Check all axis names for duplicates or invalid characters. Valid names are typically X, Y, Z, A, B, C, U, V, W, or Q1-Q9. Ensure no two axes share the same identifier.

  3. 3

    Similarly check MD1118 (AXCONF_GEOAX_NAME_TAB) for geometry axis names and ensure they correspond correctly to the machine axes without conflicts.

  4. 4

    Correct any duplicate or invalid names, save the machine data, perform a power-on reset (NCK reset), and verify the alarm is cleared.

    CAUTION: Changing axis names may affect existing part programs. Document all changes and verify program compatibility.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.