axismd.ai
Heidenhain Controller
Safety · Intermediate · 30-120 minutes
Heidenhain 905-293C - No. of safety pos.
The Heidenhain 905-293C alarm, 'No. of safety pos.,' typically occurs due to issues with the safety position data or incorrect T command configurations in the NC program. The most likely fix involves verifying and correcting the safety position parameters or adjusting the T command in the program. If unresolved, it may require deeper inspection of the control system or parameter settings.
Heidenhain 905-293C - No. of safety pos.
No. of safety pos.
Heidenhain TNC error 905-293C: No. of safety pos. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.
Root Cause Summary
The Heidenhain 905-293C alarm, 'No. of safety pos.,' typically occurs due to issues with the safety position data or incorrect T command configurations in the NC program. The most likely fix involves verifying and correcting the safety position parameters or adjusting the T command in the program. If unresolved, it may require deeper inspection of the control system or parameter settings.
Safety
Causes and Fixes
Access Machine Parameters
Log into the Heidenhain control system using the appropriate access code and navigate to the machine parameter menu (refer to the service manual for specific menu paths).
Take a screenshot or note down original values before making changes for easy rollback if needed.
Ensure the machine is in a safe, powered-down state before accessing parameters to avoid accidental movement.
Verify Safety Position Values
Check the safety position values (often under MP series parameters like MP1310 or similar). Compare them against the machine's documentation or OEM specifications.
Use the Heidenhain diagnostic tool if available to cross-verify parameter integrity.
Incorrect values can cause machine crashes; double-check inputs.
Adjust and Test Parameters
If discrepancies are found, adjust the safety position values to match the correct specifications. Save changes and perform a test cycle in manual mode to confirm the alarm clears.
Run the test cycle at reduced speed to minimize risk during verification.
Monitor for unexpected behavior during testing.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.