HEIDENHAIN 330-008F - MC change from SOM_4 to SOM_2/SOM_3 not possible

MC change from SOM_4 to SOM_2/SOM_3 not possible

The axis cannot be tested in the current safety operating mode. A different SOM mode may be required.

Root Cause Summary

Alarm 330-008F occurs when attempting to change from SOM_4 (automatic operation) to SOM_2 (MDI) or SOM_3 (handwheel) without first transitioning through SOM_1 (manual mode). This safety interlock prevents direct mode changes that could compromise machine safety.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check keylock switch position

    Physically verify the keylock switch on the machine control panel is turned to position 1 (SOM_1/Manual mode).

    Never force the keylock switch - it may be mechanically interlocked with other safety systems.

  2. 2

    Verify SOM_1 activation

    Press the operating mode key and confirm SOM_1 is displayed and active on the TNC screen before attempting mode change.

    The status bar should clearly show 'Manual' or 'SOM_1' when properly selected.

  3. 3

    Execute proper mode sequence

    From SOM_1, now select the desired target mode (SOM_2 MDI or SOM_3 Handwheel) using the operating mode keys.

    Always follow the sequence: SOM_4 → SOM_1 → SOM_2/3 for safe mode transitions.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety parameter modifications required
  • ·PLC program changes needed
  • ·Hardware keylock switch malfunction

Prevention

  • Always follow proper mode change sequence through SOM_1
  • Ensure all safety devices are properly maintained
  • Train operators on correct mode selection procedures

Common Mistakes

  • Attempting direct mode changes without going through SOM_1
  • Ignoring safety interlock status
  • Not checking for active programs before mode changes