Heidenhain codes
HeidenhainSafetyIntermediate30-120 minutes

330-003C

HEIDENHAIN 330-003C - MC S input signals not equal

MC S input signals not equal

A PLC configuration or communication error has been detected. This affects the interaction between the control and the PLC system.

Root Cause Summary

Alarm 330-003C indicates a mismatch between safety-critical input signals on the SPLC-MC (Machine Control) and SPLC-CC (Control Computer) modules. This typically occurs when emergency stop circuits, feedback signals, or safety switches show different states between the two safety controllers.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check Emergency Stop Status

    Navigate to MOD > System > Safety > Emergency Stop Status and compare ES signal states between MC and CC modules.

    Ensure all personnel are clear of machine before testing emergency stop circuits

  2. 2

    Verify E-Stop Wiring

    Check X1201/X1202 emergency stop input terminals on both SPLC modules for loose connections, corrosion, or damaged wiring.

    Use a multimeter to verify 24V signal continuity through the entire E-stop chain

  3. 3

    Test E-Stop Relays

    Manually actuate each emergency stop button and monitor relay K1/K2 operation in the safety circuit diagnostics.

    Only qualified personnel should work on safety circuits

  4. 4

    Reset Safety System

    After repairs, perform safety system reset via MOD > System > Safety > Reset Safety and verify alarm clearance.

Service Recommendedmedium confidence

Call a technician if:

  • ·Safety circuit modifications required
  • ·SPLC module replacement needed
  • ·Complex wiring diagnosis required

Prevention

  • Regular safety circuit testing
  • Periodic encoder connection inspection
  • Maintain stable 24V power supply
  • Keep safety switch contacts clean

Common Mistakes

  • Bypassing safety switches permanently
  • Ignoring intermittent signal issues
  • Not checking both SPLC modules
  • Mixing safety and non-safety grounds

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.