Heidenhain codes
HeidenhainSystemIntermediate30-120 minutes

231-8C50

HEIDENHAIN 231-8C50 - 8C50 Position input measured value not saved (EnDat)

8C50 Position input measured value not saved (EnDat)

This TNC 640 error indicates an internal control fault. The issue relates to Position value of the motor encoder was not stored.

Root Cause Summary

HEIDENHAIN alarm 231-8C50 occurs when the TNC control cannot read or store the position value from an EnDat encoder, typically due to communication failures between the encoder and the TNC system. This alarm specifically indicates that the encoder's measured position data is not being properly saved in the control's memory buffer.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check encoder cable connections

    Verify all connections at encoder head and TNC control cabinet. Check X1/X2 encoder connectors for proper seating and corrosion.

    Power down system before disconnecting encoder cables to prevent damage to EnDat interface.

  2. 2

    Inspect cable for physical damage

    Examine entire encoder cable length for cuts, pinching, or excessive bending. Pay attention to cable routing through drag chains and machine joints.

    Use TNC diagnostic screen MOD 9262 to check EnDat communication status and error counters.

  3. 3

    Measure cable continuity

    With system powered down, use multimeter to check continuity of all encoder cable conductors including shield ground connection.

    EnDat cables require impedance-controlled twisted pairs - standard multimeter testing may not reveal high-frequency signal integrity issues.

  4. 4

    Replace encoder cable if damaged

    Install new Heidenhain-approved EnDat cable with proper routing and strain relief. Ensure cable meets minimum bend radius requirements.

    Use only genuine Heidenhain EnDat cables to maintain signal integrity and EMC compliance.

DIY Feasiblehigh confidence

Call a technician if:

  • ·TNC interface board replacement required
  • ·Multiple encoder failures across axes
  • ·Persistent issues after cable and encoder replacement

Prevention

  • Regular encoder cable inspection during PM
  • Maintain proper cable routing and strain relief
  • Monitor EnDat error rates using TNC diagnostics
  • Keep encoder connections clean and properly sealed

Common Mistakes

  • Using non-Heidenhain EnDat cables
  • Improper cable shield grounding
  • Mixing encoder cable types
  • Ignoring EnDat parameter settings during encoder replacement

Seeing Multiple Alarms?