Haas Alarm 801 - Chip Conveyor Error

Chip Conveyor Fault

This alarm indicates the chip conveyor system has encountered a fault condition such as overload, jam, or the conveyor motor protection relay has tripped. The IOCON monitors the chip conveyor motor circuit and associated safety devices, and will trigger this alarm when abnormal operating conditions are detected. The conveyor will shut down to prevent motor damage or mechanical failure.

Root Cause Summary

Haas 801 Chip Conveyor Fault triggers when the NGC control detects a malfunction in the chip conveyor system, typically through conveyor motor feedback signals or limit switch inputs. This alarm protects the conveyor drive motor and prevents damage from mechanical obstructions or electrical faults in the conveyor circuit.

Safety

  • Chips may accumulate

Causes and Fixes

  1. 1

    Check Conveyor for Physical Obstructions

    Inspect the entire conveyor path for tangled chips, foreign objects, or accumulated debris blocking the conveyor belt or auger mechanism.

    Ensure machine is in E-STOP and power is locked out before manual inspection

  2. 2

    Test Manual Conveyor Operation

    Navigate to SETTING 84 (CHIP CONVEYOR) and attempt manual conveyor operation to verify motor response and listen for unusual noises.

    Normal conveyor operation should be smooth and quiet - grinding or clicking indicates mechanical issues

  3. 3

    Inspect Conveyor Drive Components

    Check conveyor drive belt tension, sprockets, and motor coupling for wear or damage that could cause binding or excessive load.

    Proper belt tension allows 1/2 inch deflection with moderate finger pressure

  4. 4

    Clear Obstruction and Reset

    Remove any found obstructions, manually rotate conveyor to verify free movement, then press RESET to clear the alarm.

    Do not force conveyor movement - investigate further if resistance is felt

DIY Feasiblehigh confidence

Call a technician if:

  • ·Motor replacement required
  • ·Interface module failure
  • ·Complex electrical troubleshooting needed
  • ·Multiple simultaneous conveyor faults

Prevention

  • Regular conveyor cleaning and lubrication
  • Monitor chip accumulation during long runs
  • Inspect limit switches monthly
  • Keep conveyor covers properly closed
  • Use proper chip breaking techniques

Common Mistakes

  • Forcing jammed conveyor manually
  • Ignoring conveyor cover interlocks
  • Operating with excessive chip load
  • Using incorrect cleaning solvents on switches
  • Adjusting motor overloads beyond nameplate values