Fanuc Alarm 4500 - REPOSITIONING INHIBITED
Fanuc Alarm 4500 occurs specifically in punch press control systems when the control detects a repositioning operation is attempted while system conditions prohibit it. This alarm is triggered when the machine is not in a valid state for repositioning, such as during active machining cycles, improper mode selection, or when interlock conditions are not satisfied.
Fanuc Alarm 4500 - REPOSITIONING INHIBITED
SYSTEM ALARM 4500
Fanuc alarm 4500: SYSTEM ALARM 4500. This alarm indicates a fault condition detected by the Fanuc control. Refer to the alarm number and name to identify the specific system or function involved.
Root Cause Summary
Fanuc Alarm 4500 occurs specifically in punch press control systems when the control detects a repositioning operation is attempted while system conditions prohibit it. This alarm is triggered when the machine is not in a valid state for repositioning, such as during active machining cycles, improper mode selection, or when interlock conditions are not satisfied.
Causes and Fixes
Check machine status on the CNC screen - verify no active M-codes or punch cycles are running. Ensure machine is in EDIT, MDI, or appropriate manual mode, not AUTO during part cycle.
Verify emergency stop is not activated and all safety interlocks are satisfied. Check I/O diagnosis screen (SYSTEM > DIAGNOSIS > I/O) for PMC signals G0000-G0007 to confirm door interlocks and safety circuits are closed.
Check parameter 6700#0 (repositioning enable) is set to 1. Navigate to SYSTEM > PARAM > PARAM and search for parameter 6700 to verify repositioning function is enabled for punch press control.
Parameter changes require parameter write enable (PWE) setting 1 and may require machine restart
Verify PMC ladder logic controlling repositioning permission signal. Check PMC address F-series flags for repositioning enable condition using SYSTEM > PMC > PMCDGN or ladder display to confirm logic allows repositioning.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.